You are here: Using The System > Icon Guide

Icon Guide

Below is a list of each icon that appears in the WEMS user interface. Some icons can have more than one state (e.g. device working normally versus device in communications failure), and these states are also covered.

Icon Name
Temperature
Boiler
2-Way Valve
3-Way Valve
Air Con
Cold & Warm
Temperature Layer
Small Pump
Large Pump
Fan
Presence
No Presence
AHU
FanCoil
VT Circuit
Modbus
Lighting
Lighting 100%
Lighting 75%
Lighting 50%
Lighting 25%
Lighting 0%
Stacking
Trading
Display
Signage
Presence
No Presence
Security
Extractor Fan
Intruder Alarm
Lock
Gas Meter
Electricity Meter
Smoke/Fire
Flood
Appliances
Bottle Fridge
TV
Coffee Machine
Running Machine
Modules
Module
States
On State
Off State
Hazard State
Type Ref Icon Description Layer Details
99 light Car Park Lighting Lighting Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTlighting Zone
24 light Centre Light Lighting Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTlighting Zone
98 light Display Lighting Lighting Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTlighting Zone
22 light Down Lighters Lighting Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTlighting Zone
20 lamp Lamp Lighting Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTlighting Zone
103 global Lighting Hold Off Lighting Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTlighting Zone
100 light Outside Lighting Lighting Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTlighting Zone
132 pir Presence Detect Lighting Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTlighting Zone
87 signlight Sign Lights Lighting Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTlighting Zone
23 light Spot Light Lighting Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTlighting Zone
96 light Stock Level Lighting Lighting Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTlighting Zone
102 light Stockroom Lighting Lighting Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTlighting Zone
19 global Switch Lighting Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTlighting Zone
97 light Trade Level Lighting Lighting Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTlighting Zone
21 light Up Lighters Lighting Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTlighting Zone
101 light Warehouse Lighting Lighting Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTlighting Zone
81 global Blinds Security/Appliances This is an appliance and therefore can only be controlled by a time of day Object Schedule
134 c_cup Coffee Machine Security/Appliances This is an appliance and therefore can only be controlled by a time of day Object Schedule
135 exercise Exercise Machine Security/Appliances This is an appliance and therefore can only be controlled by a time of day Object Schedule
77 fan Fan Security/Appliances This is an appliance and therefore can only be controlled by a time of day Object Schedule
86 fruit Gaming Machine Security/Appliances This is an appliance and therefore can only be controlled by a time of day Object Schedule
80 global Garage Door Security/Appliances This is an appliance and therefore can only be controlled by a time of day Object Schedule
74 global Gate Security/Appliances This is an appliance and therefore can only be controlled by a time of day Object Schedule
79 global PC Security/Appliances This is an appliance and therefore can only be controlled by a time of day Object Schedule
94 global Security Set/Unset Security/Appliances This is pre-configured to not appear on the web interface as it should be used with SMS Commands only
71 global Sounder Security/Appliances This is an appliance and therefore can only be controlled by a time of day Object Schedule
72 global Strobe Security/Appliances This is an appliance and therefore can only be controlled by a time of day Object Schedule
78 tv TV Security/Appliances This is an appliance and therefore can only be controlled by a time of day Object Schedule
14 global AHU Cooling Stages Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
16 heatvalve AHU Cooling Valve Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
12 global AHU Dampers Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
73 fan AHU Extract Fan Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
11 fan AHU Fans Temperature Layer This can be controlled by an Object Schedule, a SMARTheating Zone or within the AHU Control Module
108 heatvalve AHU Heat For Battery Valve Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
13 global AHU Heating Stages Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
15 heatvalve AHU Heating Valve Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
105 fan AHU Supply Fan Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
95 ahu_split Air Conditioning Temperature Layer This can be controlled by a normal Object Schedule or by a SMARTheating Zone but can only be controlled Time vs On/Off within a Zone as it comes with a deadband
18 global Alarm Output Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
1 boiler Boiler Temperature Layer This is a Global Object and therefore requires another relay to control it
3 pump Boiler Pump Temperature Layer This is a Global Object and therefore requires another relay to control it
85 bottle Bottle Cooler Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
159 global Chiller Temperature Layer This can be controlled by a normal Object Schedule or by a SMARTheating Zone but can only be controlled Time vs On/Off within a Zone as it comes with a deadband
2 boiler Combi Boiler Temperature Layer This is a Global Object and therefore requires another relay to control it
157 fan Door Curtain Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
10 panelheat Electric Panel Heater Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
91 panelheat Electric Panel Heater (slave) Temperature Layer This is a Global Object and therefore requires another relay to control it
93 global Engine Reset Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
107 fan Extract Fan Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
137 global FPAHU Cool Enable Temperature Layer This is a bespoke Object designed for control within an FPAHU and should only be used for this purpose
136 global FPAHU Enable Temperature Layer This is a bespoke Object designed for control within an FPAHU and should only be used for this purpose
139 global FPAHU Fan Low Speed Enable Temperature Layer This is a bespoke Object designed for control within an FPAHU and should only be used for this purpose
138 global FPAHU Pemp Enable Temperature Layer This is a bespoke Object designed for control within an FPAHU and should only be used for this purpose
106 fan Fresh Air Supply Fan Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
17 heatvalve Gas Valve Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
109 global Heating Hold Off Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
5 heatvalve Heating Valve Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
6 heatvalve Hot Water Valve Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
158 global HVAC Panel Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
104 pump HWS Primary Pump Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
83 pump HWS Secondary Pump Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
9 immersion Immersion Heater Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
8 manifold Manifold Pump Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
4 pump Pump Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
70 global Reset Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
110 panelheat Storage Heater Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
92 global Towel Rail Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
84 zone_pump Zone Pump Temperature Layer This has no unique features and therefore can be controlled normally by an Object Schedule or by a SMARTheating Zone
7 zonevalve Zone Valve Temperature Layer This is a Global Object and therefore requires another relay to control it

Digitals

Type Ref Icon Description Layer Details Warning Symbol
125 elec_met Electricity Meter Safety/Metering Layer This measures pulses and will also appear in the SMARTmetering page No
90 smoke Fire Safety/Metering Layer This is a fault/warning digital and will put the system into Fire Active Mode when activated Yes
45 global Flood Safety/Metering Layer This is a fault/warning digital Yes
46 global Gas Alarm Safety/Metering Layer This is a fault/warning digital Yes
126 elec_met Gas Meter Safety/Metering Layer This measures pulses and will also appear in the SMARTmetering page No
140 genny Generator Safety/Metering Layer No  
142 pfc PFC Safety/Metering Layer No  
44 smoke Smoke Safety/Metering Layer This is a fault/warning digital and will put the system into Fire Active Mode when activated Yes
141 batt UPS Safety/Metering Layer No  
127 elec_met Water Meter Safety/Metering Layer This measures pulses and will also appear in the SMARTmetering page No
43 DC_anim Door Contact Security/Appliances Layer This is a status digital No
112 global Final Exit Key Switch Security/Appliances Layer This is a status digital and will put the system into Security Set Mode when activated No
88 intruder Intruder Active Security/Appliances Layer This is a warning/fault digital and will also put the system in Intruder Active Mode when activated Yes
76 global Panic Button Security/Appliances Layer This is a status digital No
42 Pir Pir Sensor Security/Appliances Layer This is a status digital No
89 global Security Fault Security/Appliances Layer This is a fault/warning digital Yes
75 set_unset Security Set/Unset Security/Appliances Layer This is a status digital and will put the system into Security Set Mode when activated No
111 DC_anim Warehouse Door Open Security/Appliances Layer This is a status digital No
116 global AC Filter Dirty Temperature Layer This is a fault/warning digital Yes
115 global AHU Filter Dirty Temperature Layer This is a fault/warning digital Yes
32 global AHU Return Air Flow Temperature Layer This is a status digital No
31 global AHU Supply Air Flow Temperature Layer This is a status digital No
25 global Boiler Fault Temperature Layer This is a fault/warning digital Yes
29 global Boiler High Temp Temperature Layer This is a fault/warning digital Yes
26 global Boiler Status Temperature Layer This is a status digital No
33 global Burner Fault Temperature Layer This is a fault/warning digital Yes
41 global Common Fault Temperature Layer This is a fault/warning digital Yes
39 global Cooling Fault Temperature Layer This is a fault/warning digital Yes
38 global Emergency Stop Temperature Layer This is a status digital No
114 global Extract Fan Fault Temperature Layer This is a fault/warning digital Yes
40 global Heating Fault Temperature Layer This is a fault/warning digital Yes
37 global Motor Trip Temperature Layer This is a fault/warning digital Yes
128 presence Presence Detect Temperature Layer This is a status digital No
27 global Pump Fault Temperature Layer This is a fault/warning digital Yes
28 global Pump Status Temperature Layer This is a status digital No
113 global Supply Fan Fault Temperature Layer This is a fault/warning digital Yes
30 global Valve Status Temperature Layer This is a status digital No

Analogue

Type Ref Icon Description Layer Details
58 light_lev Outside Light Lighting Layer This measures Light Level in LUX and then converts it into a % value. This is required to create a SMARTlighting Zone
57 light_lev Room Light Lighting Layer This measures Light Level via LUX and then converts it into a % value. This is required to create a SMARTlighting Zone
60 global Smart Sensor Battery Modules This measures the battery voltage on a Wireless Sensor. This is required to set alarm triggers to spot when the battery is running low
54 global Air Quality Temperature Layer For the measurement of CO2 via a 0–10v input
47 room_temp Boiler Flow Temp Temperature Layer This measures temperature in Degrees Celsius (°C). This can be used to control a SMARTheating Zone
48 room_temp Boiler Return Temp Temperature Layer This measures temperature in Degrees Celsius (°C). This can be used to control a SMARTheating Zone
121 room_temp Canteen Temp Temperature Layer This measures temperature in Degrees Celsius (°C). This can be used to control a SMARTheating Zone
123 room_temp Entrance Temp Temperature Layer This measures temperature in Degrees Celsius (°C). This can be used to control a SMARTheating Zone
82 room_temp Fridge Temp Temperature Layer This measures temperature in Degrees Celsius (°C). This can be used to control a SMARTheating Zone
59 room_temp Hot Water Temp Temperature Layer This measures temperature in Degrees Celsius (°C). This can be used to control a SMARTheating Zone
124 room_temp Managers Office Temp Temperature Layer This measures temperature in Degrees Celsius (°C). This can be used to control a SMARTheating Zone
49 room_temp Manifold Temp Temperature Layer This measures temperature in Degrees Celsius (°C). This can be used to control a SMARTheating Zone
119 room_temp Office Temp Temperature Layer This measures temperature in Degrees Celsius (°C). This can be used to control a SMARTheating Zone
50 room_temp Outside Air Temp Temperature Layer This measures temperature in Degrees Celsius (°C). This can be used to control a SMARTheating Zone
56 global Return Air Humidity Temperature Layer For the measurement of humidity via a 0–10v input
117 room_temp Return Air Temp Temperature Layer This measures temperature in Degrees Celsius (°C). This can be used to control a SMARTheating Zone
55 global Room Humidity Temperature Layer For the measurement of humidity via a 0–10v input
51 room_temp Room Temp Temperature Layer This measures temperature in Degrees Celsius (°C). This can be used to control a SMARTheating Zone
118 room_temp Sales Temp Temperature Layer This measures temperature in Degrees Celsius (°C). This can be used to control a SMARTheating Zone
52 room_temp Supply Air Temp Temperature Layer This measures temperature in Degrees Celsius (°C). This can be used to control a SMARTheating Zone
122 room_temp Training Room Temp Temperature Layer This measures temperature in Degrees Celsius (°C). This can be used to control a SMARTheating Zone
120 room_temp Warehouse Temp Temperature Layer This measures temperature in Degrees Celsius (°C). This can be used to control a SMARTheating Zone

Analogue Outputs

Type Ref Icon Description Layer Details
129 global Ahu Dampers Temperature Layer This is a 0-10v signal output for use in the AHU/FanCoil
130 global AHU Heating Stages Temperature Layer This is a 0-10v signal output for use in the AHU/FanCoil
131 global AHU Cooling Stages Temperature Layer This is a 0-10v signal output for use in the AHU/FanCoil
133 fan AHU Supply Fan Temperature Layer This is a 0-10v signal output for use in the AHU/FanCoil
160 fan AHU Extract Fan Temperature Layer This is a 0-10v signal output for use in the AHU/FanCoil
161 fan VT Circuit Valve Temperature Layer This is a 0-10v signal output for use in the VT Control Module

Rako

Type Ref Icon Description Layer Details
150 global Lights Lighting Layer This will replicate the 4 different lighting scene commands available to any previously configured Rako Lighting Dimmer
151 global Vertical Blinds Lighting Layer This will replicate the 3 different Blind/Curtain commands available to any previously configured Rako Blind/Curtain Controller
152 global Horizontal Blinds Curtains Lighting Layer This will replicate the 3 different Blind/Curtain commands available to any previously configured Rako Blind/Curtain Controller

Modbus

Type Ref Icon Description Layer
153 modb_ahu Modbus AHU Temperature Layer

Modbus Amps

Type Ref Icon Description Layer
154 elec_met Modbus Amps P1 Safety/Metering Layer
155 elec_met Modbus Amps P2 Safety/Metering Layer
156 elec_met Modbus Amps P3 Safety/Metering Layer

WEMS User Guide version 4.0 20150130.
This guide relates to features up to and including 1.18.0.3